Physical characteristics
Dimensions 9.75(d) x 8.13(w) x 1.75(h) in. (24.77 x 20.65 x 4.45 cm) (1U height)
Weight 3.3 lb. (1.5 kg)
Memory and processor
Processor Intel Core 2 Duo T9400 @ 2400 MHz, 8 GB DDR3 DIMM; storage: 250 GB SATA II 7200 rpm hard disk drive, 4 GB compact flash
Environment
Operating temperature 32°F to 122°F (0°C to 50°C); Important: See note for 50°C temperature spec rules
Operating relative humidity 15% to 90% @ 122°F (50°C), noncondensing
Nonoperating/Storage temperature 14°F to 149°F (-10°C to 65°C)
Nonoperating/Storage relative humidity 15% to 95% @ 149°F (65°C), noncondensing
Altitude up to 10,000 ft. (3 km)
Electrical characteristics
Maximum heat dissipation 140 BTU/hr (147.7 kJ/hr), 266 BTU/hr (287 kJ/hr)
Idle power 41 W
Maximum power rating 78 W
Notes Idle power is the actual power consumption of the device with no ports connected.; Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
Notes
  The services module can only be used with certified AllianceONE services applications. It does not support a general application environment.
  • Chassis operating temperature specifications when the services module is installed:
  • For the 5400zl chassis, if all modules are installed in the left side of the chassis, the temperature specification is set to 50°C for the chassis.
  • If any modules are installed on the right side of the chassis, then the temperature specification for the chassis is 45°C.
  • For the 8200zl chassis, the temperature specification is set to 45°C.
  • A maximum of 4 of these modules may be installed in any zl switch (except the 8206zl chassis, which supports a maximum of 2 of these modules).
  • If a module is installed in excess of these quantities, the module will not boot.
  • If you are running a 5406zl and want the 50°C temperature specification, then only three modules are supported in the chassis as that is all the slots there are on the left side.
  • When the services module is installed, the maximum relative humidity for the switch drops from 95% to 90%.